The E1 interface meets all requirements of ITU recommendations G.703, G.704, G.706 and G.732. It supports both two and 16 frames per multiframe, with or without CRC-4. Zero suppression over the line is HDB3. The integral LTU ensures a range of up to 2 km (1.2 miles).
The T1 interface meets all requirements of TR-62411 and TR-62421. It supports both D4 and ESF frame formats. Zero suppression over the line is selectable for either transparent, B7ZS or B8ZS. The integral CSU ensures a range of up to 1.6 km (1 mile).
Setup, control and monitoring of status and diagnostics can be performed via an ASCII terminal. The FCD-E1M and FCD-T1M modular access multiplexers can also be managed via any standard SNMP application or the RADview SNMP network management application. In-band management is available via TS0 (E1) or datalink bit (T1), or a dedicated timeslot using standard Frame Relay (RFC 1490), PPP and RIP II routing protocols.
The FCD-E1M and FCD-T1M modular access multiplexers support dial-in/dial-out, which can also be used for remote out-of-band configuration and monitoring, via serial V.24, SLIP, PPP or Ethernet ports. Enhanced diagnostics include user-activated local and remote loopbacks, an integrated BER tester and fractional E1/T1 in-band loops.
The FCD-E1M and FCD-T1M modular access multiplexers are available as 19", 1U-high, standalone units for desktop use. A rack-mount adapter kit enables installation in a 19" rack.